GuideUK
EICR remedial work follow-up for electricians: codes, 28 days and approvals
EICR remedial work follow-up means getting the landlord or letting agent to approve and book the C1, C2 and FI work on an unsatisfactory report before the legal deadline. In England, the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require the landlord to have that work done within 28 days starting with the date of the inspection, or sooner if the report says so. The duty is the landlord's, but a quick quote and a dated follow-up schedule make it far easier for them to meet it.
On this page
- EICR codes and what each one means for the landlord
- Before and after
- The 28-day deadline, and when it starts
- Where remedial work stalls
- A follow-up workflow for remedial quotes
- Remedial quote follow-up template
- A remedial work tracker you can copy
- What stays with you
- How Mike Automations would build this
- Free tools for remedial quotes
- What it looks like in practice
- What it costs
- Common questions
- Sources
EICR remedial work follow-up is where many electricians who test rented homes lose time and jobs. The inspection is done, the report says unsatisfactory, and the remedial quote goes to a letting agent who forwards it to a landlord who is on holiday. Meanwhile the 28 days are running. This page sets out the codes and the deadline as the regulations and the gov.uk guidance describe them, then gives you a follow-up workflow, a message template and a tracker you can copy. It covers England. Wales and Scotland have their own rules.
EICR codes and what each one means for the landlord
The gov.uk guidance for landlords (published November 2025) uses these codes. A C1 or C2 means the report will say the installation is unsatisfactory for continued use. For the letting agent, the remedial job then runs through their maintenance request workflow. The guidance also says the inspector may make any C1 hazard safe before leaving.
| Code | Meaning (gov.uk wording) | Must the landlord act? |
|---|---|---|
| C1 | Danger present. Risk of injury | Yes, within 28 days or a shorter period in the report |
| C2 | Potentially dangerous | Yes, within 28 days or a shorter period in the report |
| FI | Further investigation required without delay | Yes, the investigation must be carried out in the same period |
| C3 | Improvement recommended | No. The guidance says C3 alone doesn't stop a report being satisfactory |
Before and after
The same job, before and after the workflow. For illustration.
| Today | With the workflow | |
|---|---|---|
| After an unsatisfactory report | The quote goes out, then nothing | The quote goes out with the deadline explained, and the follow-ups start |
| Follow-ups | When you remember, between jobs | On a schedule that respects the deadline, stopped when the landlord approves |
| Approval | A phone call you have to chase | A yes by reply or e-signature, logged against the report |
| Booking the work | More phone calls | The approved job goes into your diary with the property details |
| The satisfactory report | Sent eventually | Sent and filed the day the work is done |
The 28-day deadline, and when it starts
Regulation 3(4) of the 2020 regulations says the landlord must make sure the further investigative or remedial work is carried out by a qualified person within 28 days, or within the period specified in the report if that is less, "starting with the date of the inspection and testing". So the clock starts on the day you test, not the day you send the report or the quote. Some summaries online are vaguer, so go by the regulation and by what your own report says. Once the work is done, regulation 3(5) says the landlord must get written confirmation from a qualified person and send it, with the report, to each tenant and to the local council within 28 days of completion. The gov.uk guidance lists a satisfactory EICR, an Electrical Installation Certificate (EIC) or a Minor Electrical Installation Works Certificate (MEIWC) as acceptable confirmation. If a landlord doesn't do the work, the council can serve a remedial notice, and the guidance says councils can impose a financial penalty of up to £40,000. Since the 2025 amendment, the same rules also apply to social landlords in England.
Where remedial work stalls
- The report and the quote arrive in one long email, and the landlord reads the report but not the price
- The agent has to forward it, and the landlord's approval comes back to the agent, not to you
- Nobody writes down the deadline date, so everyone thinks there's more time than there is
- Approval comes, but booking access with the tenant takes another week
- The work is done, but the certificate sits in your van and the landlord can't send it on
A follow-up workflow for remedial quotes
- Inspection day: log the property, the inspection date, the codes found and the deadline date. Put the deadline a day or two early in your tracker, since the period starts with the inspection day itself.
- Within 24 hours: send the report and a separate remedial quote to whoever instructed you. List each C1, C2 and FI item, its price, and the deadline date in plain words.
- Day 3 after the inspection: if there's no approval, send the follow-up message below, by email or on WhatsApp.
- Day 7: a second follow-up offering two dates for the work. If an agent instructed you, ask whether they need anything from you to get the landlord's answer.
- Day 14: a final message stating the deadline date clearly and asking for a yes or no. Keep a dated copy of everything you sent.
- On approval: book the work and arrange access with the tenant or agent the same day.
- On completion: issue the EIC or MEIWC that day and send it to whoever instructed you, with a reminder that the landlord has 28 days from completion to send it to the tenants and the council.
Remedial quote follow-up template
Subject: [address]: EICR remedial work, approval needed by [date] Hi [name], Following the electrical inspection at [address] on [inspection date], the report found [number] items that need remedial work or further investigation ([codes, e.g. two C2 and one FI]). The quote for this work is attached: [amount]. Under the electrical safety regulations for rented homes in England, this work needs to be completed within 28 days of the inspection date, which means by [deadline date], or sooner if the report says so. I can do the work on [date] or [date]. If you reply "approved" with your preferred date, I'll arrange access with the tenant and send the certificate as soon as the work is done. If you'd like another electrician to do it, that's fine, just let me know so I can update my records. Thanks, [your name] [business, phone]
A remedial work tracker you can copy
One row per report. A shared Google Sheet is enough to start. For illustration only, with made-up addresses and dates:
| Property | Inspection date | Codes | Deadline | Quote sent | Approved | Booked | Confirmation sent |
|---|---|---|---|---|---|---|---|
| Flat 2, 10 Example Road | 3 Nov | 2 x C2, 1 x FI | 30 Nov | 4 Nov | 7 Nov | 12 Nov | 12 Nov |
| 14 Sample Street | 5 Nov | 1 x C1 (made safe), 1 x C2 | 2 Dec | 5 Nov | Chased 8 Nov |
What stays with you
Your coding, your quote and your professional judgement. A workflow can log the dates, send the follow-ups on time, stop when someone replies and show you which properties are close to their deadline. The same approach covers job sign-off and completion photos once the work is done, and the paperwork for solar PV installs. It doesn't decide what's dangerous or what the work costs, and if AI drafts a message to a landlord, a person always approves it first.
How Mike Automations would build this
A free 15-minute call about how your reports and quotes go out today. Within 48 hours you get a written plan with a fixed price and a clear definition of "working". It's built on the tools you already use (your certification software's exports, your email, Google Sheets), so there's nothing new to learn. Live in 2-3 days. Workflow automation is a fixed $2,000, and you pay once it's running and you're happy with it.
Free tools for remedial quotes
The free quote generator turns the EICR remedial list into a priced quote PDF, and the quote follow-up message generator writes the nudge when the customer goes quiet.
ExampleFor illustration
What it looks like in practice
For illustration: you test a rented flat on 3 November and record two C2s. That evening the agent gets the report and a one-page remedial quote with the deadline date in the subject line. On 6 November, with no answer, the follow-up goes out automatically. The agent replies "approved" on the 7th, you book the 12th, and the Minor Works certificate goes to the agent that afternoon. The tracker row is complete.
What it costs
Workflow automation is a fixed $2,000, paid once it's running and you're happy with it. The first 3 businesses pay $1,500. Optional support is $150 a month. You get the exact scope and price in a written plan after a free 15-minute call.
Book a free 15-minute callBuild your plan for thisEmail me
No pitch. In 15 minutes you'll know if it's worth building.
One person, Michael, a software engineer, builds it. Fixed price in writing, and you pay only once it's live and you're happy with it.
Common questions
When do the 28 days start?
Regulation 3(4) says the period starts with the date of the inspection and testing. If your report gives a shorter period for an item, that shorter period applies.
Does a C3 have to be fixed?
No. The gov.uk guidance says a C3 means improvement is recommended and doesn't stop a report being satisfactory. You can still quote for it, kept separate from the required work.
Who sends the confirmation to the council?
The landlord, or their agent. The regulations put the duty on the landlord to send the written confirmation and the report to tenants and the council within 28 days of completion. You make that easy by sending the certificate promptly.
How much does it cost?
Workflow automation is a fixed $2,000, paid once it's running and you're happy with it. The first 3 businesses pay $1,500. Optional support is $150 a month.
Sources
The facts on this page were checked against these official sources, last on .
- legislation.gov.uk: Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, regulation 3legislation.gov.uk
- GOV.UK: Electrical safety standards in the private and social rented sectors, guidancegov.uk
- legislation.gov.uk: Electrical Safety Standards (Amendment) (Extension to the Social Rented Sector) Regulations 2025legislation.gov.uk
Read next
- Estimate Follow-Up Email Templates for Contractors (+ Texts)Estimate follow-up email templates for contractors: a day-by-day sequence, 5 emails, 2 texts and a reply to "your price is too high". Copy and paste.
- How to Ask for a Deposit on a Quote (With Templates)How to ask for a deposit on a quote: when it makes sense, wording for the quote and invoice, UK and US cancellation rules, and a deposit that books the job
- Professional Clearance Letter Template for UK AccountantsA professional clearance letter template for UK accountants: the request, the reply, a chase sequence and a tracker, based on ICAEW and ACCA guidance.
More guides
- Certificate reminders for letting agentsGas safety, EICR and EPC reminders for letting agents: the renewal dates in England, a timeline table and a workflow that books and files each certificate.
- WhatsApp quote follow-up for tradespeopleWhatsApp quote follow-up for tradespeople: a 3-message sequence with timing, how Meta's templates and opt-in rules work, and what to automate.
- Home service contractors (US)Estimate follow-up automation for US home service contractors: follow up every estimate, remind customers before visits, log every lead. Live in 2-3 days.
- Automated invoice payment remindersAutomated invoice payment reminders that go out on schedule, stop the moment a client pays, and give you a short list of who needs a personal call.
- All workflow guides